| MAIN |
| Range of product |
Preventa XY2 |
| Product or component type |
Latching emergency stop rope pull switch |
| Device short name |
XY2CE |
| Housing colour |
Red RAL 3000 |
| Overvoltage category |
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030 |
| COMPLEMENTARY |
| Local signalling |
Without pilot light |
| Number of cables |
1 |
| Trigger cable maximum length |
70 m |
| Body material |
Zamak |
| Cover material |
Stainless steel |
| Reset |
By booted push-button |
| Contacts type and composition |
1 NC + 1 NO |
| Contact operation |
Slow-break |
| Trigger cable anchor point |
RH side |
| Connections – terminals |
Screw clamp terminal, 1 x 0.5…2 x 1.5 mm² |
| Tightening torque |
0.8…1.2 N.m |
| Cable entry number |
3 plain hole for Pg 13.5 or ISO M20 cable gland |
| Safety level |
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 |
| Safety reliability data |
B10d = 300000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear |
| Marking |
CE |
| Mechanical durability |
60000 cycles |
| Distance between cable supports |
5 m |
| [Ie] rated operational current |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current |
10 A |
| [Ui] rated insulation voltage |
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14 |
| [Uimp] rated impulse withstand voltage |
6 kV EN/IEC 60947-1 |
| Positive opening |
With conforming to EN/IEC 60947-5-1 |
| Maximum resistance across terminals |
25 MOhm conforming to EN/IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A |
| Short-circuit protection |
10 A cartridge fuse type gG conforming to EN/IEC 60269 |
| Terminals description ISO n°1 |
(13-14)NO
(21-22)NC |
| Net weight |
1.45 kg |
| Compatibility code |
XY2CE |
| ENVIRONMENT |
| Standards |
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60947-5-5
UL 508
EN/ISO 13850
Work equipment directive 2009/104/EC
EN/IEC 60204-1
Machinery directive 2006/42/EC |
| Product certifications |
UL category NISD emergency stop devices
CSA
CCC |
| Protective treatment |
TC |
| Ambient air temperature for operation |
-25…70 °C |
| Ambient air temperature for storage |
-40…70 °C |
| Vibration resistance |
10 gn (f= 10…300 Hz) conforming to EN/IEC 60068-2-6 |
| Shock resistance |
50 gn 11 ms conforming to EN/IEC 60068-2-27 |
| IP degree of protection |
IP66 conforming to IEC 60529 |
| PACKING UNITS |
| Unit Type of Package 1 |
PCE |
| Number of Units in Package 1 |
1 |
| Package 1 Weight |
1.552 kg |
| Package 1 Height |
9 cm |
| Package 1 width |
16 cm |
| Package 1 Length |
20 cm |
| Package 2 Weight |
9.849 kg |
| Package 3 Weight |
88.7 kg |
| OFFER SUSTAINABILITY |
| Sustainable offer status |
Green Premium product |
| REACh Regulation |
REACh Declaration |
| EU RoHS Directive |
EU RoHS Declaration |
| Mercury free |
Yes |
| RoHS exemption information |
Yes |
| Environmental Disclosure |
Product Environmental Profile |